Lincoln, NE water hardness
Lincoln Water System publishes an average hardness of 192 mg/L (11.2 grains per gallon, also its own figure) for its system, in its City of Lincoln 2025 Annual Drinking Water Quality Report. On the USGS scale that is very hard water, though the utility's own range crosses more than one class — it spans hard and very hard water from end to end.
The published figure, exactly as it appears
This is the hardness line transcribed from the source, with nothing added:
Total Hardness 192 ppm or 11.2 grains per gallon 180 - 236 ppm or 10.3 - 12.6 grains per gallon 2025
Lincoln Water System, City of Lincoln 2025 Annual Drinking Water Quality Report
Units as published: ppm, with grains per gallon given alongside. What kind of figure it is: an average with a range. Retrieved 2026-10-17.
Lincoln hardness in mg/L and grains per gallon
Water-quality reports use mg/L (identical to ppm). Softener instructions and plumbing specifications use grains per gallon. Both are below. Where a figure is our arithmetic rather than the utility's own number, it says so.
| Figure | mg/L (ppm) | Grains per gallon | Whose number |
|---|---|---|---|
| Published average | 192 | 11.2 | both published by the utility |
| Low end of published range | 180 | 10.3 | both published by the utility |
| High end of published range | 236 | 12.6 | both published by the utility |
| Plotted on the scale above | 192 | 11.2 | published average; the gpg here is our conversion at 17.1, so it can differ slightly from a utility’s own rounded gpg figure |
The conversion, both ways: gpg = mg/L ÷ 17.1 and mg/L = gpg × 17.1. Worked for this system: 192 ÷ 17.1 = 11.2 gpg. The converter does °dH and °f as well, and why the factor is 17.1 explains where the number comes from.
What this figure does not tell you
Service area and source water
| Utility | Lincoln Water System |
|---|---|
| Service area as published | Lincoln Water System's distribution system. The utility's own water quality FAQ states that all the water served in the city has nearly the same level of hardness. |
Provenance of every number on this page
| Source document | City of Lincoln 2025 Annual Drinking Water Quality Report |
|---|---|
| Source URL | https://www.lincoln.ne.gov/files/sharedassets/public/v/12/ltu/utilities/water-system/water-quality-report.pdf |
| Published by | Lincoln Water System |
| Report year | 2025 |
| Year note | Data collected between January 1 and December 31, 2025. The hardness line is in the report's “Additional Water Quality Parameters” table, tested monthly in the distribution system. |
| Retrieved | 2026-10-17 |
| Classification bands | USGS Water Science School, retrieved 2026-10-16 |
Notes the report forces on this page
- The hardness line is printed across several lines of a table in the report; the quote above joins those cells in the order they appear.
- Lincoln's own grains-per-gallon figures are shown as published and are not a straight conversion of its ppm figures. Its average converts cleanly — 192 divided by 17.1 is 11.2 — but its range ends convert to 10.5 and 13.8 against its published 10.3 and 12.6.
If you are sizing a softener for Lincoln water
At 11.2 gpg, the sizing arithmetic starts from your household's water use, not from the hardness alone. The calculator below is pre-filled with this system's figure and every other input is an editable assumption.
Whether a softener is worth installing at this hardness is a judgement, not arithmetic, and it is not one this site makes for you. Nothing here has been tested by the author.
Where Lincoln sits against other verified systems
- Portland, OR 9 mg/L 0.5 gpg Soft
- Boston, MA 16 mg/L 1 gpg Soft
- Manchester, NH 17.9 mg/L 1 gpg Soft
- Raleigh, NC 25 mg/L 1.47 gpg Soft
- New York, NY 32 mg/L 2 gpg Soft
- Charlotte, NC 32 mg/L 1.9 gpg Soft
- Memphis, TN 46 mg/L 2.7 gpg Soft
- Anchorage, AK 56 mg/L 3.3 gpg Soft
- Oakland, CA 68.4 mg/L 4 gpg Moderately hard
- Nashville, TN 77.3 mg/L 4.5 gpg Moderately hard
- Sacramento, CA 83 mg/L 4.9 gpg Moderately hard
- Fresno, CA 89.3 mg/L 5.2 gpg Moderately hard
- Saint Paul, MN 90 mg/L 5 gpg Moderately hard
- Austin, TX 93 mg/L 5.4 gpg Moderately hard
- Washington, DC 95 mg/L 5.6 gpg Moderately hard
- Birmingham, AL 98 mg/L 5.7 gpg Moderately hard
- Kansas City, MO 100 mg/L 5.8 gpg Moderately hard
- Denver, CO 105 mg/L 6.1 gpg Moderately hard
- Tulsa, OK 114.5 mg/L 6.7 gpg Moderately hard
- Louisville, KY 115 mg/L 6.7 gpg Moderately hard
- Columbus, OH 120 mg/L 7 gpg Moderately hard
- Cleveland, OH 120 mg/L 7 gpg Moderately hard
- Philadelphia, PA 125 mg/L 7.3 gpg Hard
- Ann Arbor, MI 126 mg/L 7.4 gpg Hard
- Cincinnati, OH 133 mg/L 7.8 gpg Hard
- Milwaukee, WI 137 mg/L 8.01 gpg Hard
- St. Louis, MO 138 mg/L 8.1 gpg Hard
- Fort Worth, TX 145 mg/L 8.5 gpg Hard
- Honolulu, HI 162.5 mg/L 9.5 gpg Hard
- Wichita, KS 170 mg/L 9.9 gpg Hard
- Omaha, NE 170 mg/L 10 gpg Hard
- Los Angeles, CA 192 mg/L 11.2 gpg Very hard
- Lincoln, NE 192 mg/L 11.2 gpg Very hard
- Tampa, FL 220 mg/L 12.9 gpg Very hard
- Phoenix, AZ 237 mg/L 13.9 gpg Very hard
- Mesa, AZ 239.4 mg/L 14 gpg Very hard
- San Diego, CA 276 mg/L 16 gpg Very hard
- Las Vegas, NV 280 mg/L 16 gpg Very hard
- Chandler, AZ 282.2 mg/L 16.5 gpg Very hard
- San Antonio, TX 299.3 mg/L 17.5 gpg Very hard
- Anaheim, CA 300 mg/L 18 gpg Very hard
- Indianapolis, IN 317 mg/L 19 gpg Very hard
- Madison, WI 324.9 mg/L 19 gpg Very hard
- Scottsdale, AZ 352.5 mg/L 20.6 gpg Very hard
mg/L as calcium carbonate. Each classification band is drawn the same width, so the axis is not linear in mg/L.
Systems with similar published hardness
- Los Angeles, CA Los Angeles Department of Water and Power, 192 mg/L (11.2 gpg)
- Wichita, KS City of Wichita Water Utilities, 170 mg/L (9.9 gpg)
- Omaha, NE Metropolitan Utilities District, 170 mg/L (9.9 gpg)
- Tampa, FL City of Tampa Water Department, 220 mg/L (12.9 gpg)
All 44 verified systems How to find hardness in your own utility's report If you are on a well instead